Type: Armoured Electric Cable
Rated Voltage: 0.6/1kV~26/35kV
Conductor: Hard drawn aluminum or annealed copper
Insulation: XLPE or PVC
Filler: Polypropylene tape (pp tape)
Wrap Tape: Non-woven fabric or PP wrapping tape
Armour: Steel tape armoured or steel wire armoured or aluminum wire armoured
Outer Sheath: Polyvinyl chloride (PVC)
Nominal cross-sectional area(mm2) | Diameter of conductor (mm) | insulation thickness(mm) | Outer sheath thickness(mm) | Approx overall diameter(mm) | Cable Approx. Weight kg/km | |
YJV32 | YJLV32 | |||||
25 | 6.0 | 3.4 | 1.8 | 26.6 | 1643 | 1384 |
35 | 7.0 | 3.4 | 1.8 | 27.6 | 1821 | 1499 |
50 | 8.3 | 3.4 | 1.9 | 29.1 | 2027 | 1628 |
70 | 9.8 | 3.4 | 1.9 | 30.6 | 2329 | 1810 |
95 | 11.5 | 3.4 | 2.0 | 32.5 | 2689 | 1999 |
120 | 12.9 | 3.4 | 2.0 | 33.9 | 3037 | 2192 |
150 | 14.5 | 3.4 | 2.1 | 35.7 | 3419 | 2384 |
185 | 16.0 | 3.4 | 2.2 | 38.4 | 4147 | 2868 |
240 | 18.3 | 3.4 | 2.3 | 40.9 | 4842 | 3222.6 |
300 | 20.5 | 3.4 | 2.4 | 43.3 | 5637 | 3606 |
400 | 23.5 | 3.4 | 2.5 | 46.7 | 6701 | 4115 |
500 | 26.7 | 3.4 | 2.6 | 50.2 | 7992 | 4724 |
630 | 29.9 | 3.4 | 2.7 | 54.0 | 9457 | 5414 |
6/6kv 6/10kv 3-Core XLPE insulated Steel Wire Armoured PVC/PE Sheathed Power Cable | ||||||
Nominal cross-sectional area(mm2) | Diameter of conductor (mm) | insulation thickness(mm) | Outer sheath thickness(mm) | Approx overall diameter(mm) | Cable Approx. Weight kg/km | |
YJV32 | YJLV32 | |||||
25 | 6.0 | 3.4 | 2.5 | 48.0 | 4229 | 3766 |
35 | 7.0 | 3.4 | 2.6 | 50.6 | 4771 | 4117 |
50 | 8.3 | 3.4 | 2.7 | 53.6 | 5456 | 4571 |
70 | 9.8 | 3.4 | 2.8 | 57.2 | 6352 | 5101 |
95 | 11.5 | 3.4 | 2.9 | 61.1 | 7539 | 5765 |
120 | 12.9 | 3.4 | 3.0 | 64.5 | 8578 | 6334 |
150 | 14.5 | 3.4 | 3.2 | 68.6 | 9901 | 7080 |
185 | 16.0 | 3.4 | 3.3 | 72.0 | 11095 | 7727 |
240 | 18.3 | 3.4 | 3.5 | 77.5 | 13254 | 8844 |
300 | 20.5 | 3.4 | 3.7 | 84.2 | 16678 | 11015 |
400 | 23.5 | 3.4 | 3.9 | 91.4 | 20051 | 12698 |
500 | 26.7 | 3.4 | 4.1 | 99.2 | 24221 | 14780 |
630 | 29.9 | 3.4 | 4.4 | 107.3 | 28839 | 17052 |
Armoured Cable
A hard-wearing armoured cable is essential in harsher environments. If a standard cable is ran through areas such as building sites or a factory, it may increase the chance of power loss or electrical cut outs. Armoured cable can be used for numerous applications which require an uninterrupted and worry free power connection.
When is armoured cable required?
The best use of this cable would be if the intended application is likely to be on a rough surface, or is situated in areas where there is high traffic and risk of debris striking the power cable. This would be the most beneficial. As an example, some of the applications for using SWA cable include:
• Underground cabling
• Train tracks
• Outdoor building sites
• Indoor and outdoor power stations
• High risk workshops
What types of armoured cable are available?
In terms of the actual armoured design of these cables, each product is a galvanized SWA cable (Steel Wire Armour). The outer sheath of each cable can vary. However, the more common selections would be a PVC sheathing, rated as LSZH (Low Smoke Zero Hydrogen).